Z5M

Zoning Mixer

953.019UK

Introduction

Thank you for choosing this Adastra zoning mixer. The Z5M is a professional 1U mixer offering many features to give versatile control for up to 5 stereo output zones. In order to achieve the best results from this equipment and avoid damage through misuse, please read and follow these instructions and retain for future reference.

Version 1.1

Caution: Please read this manual carefully before operating. Damage caused by misuse is not covered by the warranty.

Warning:

To prevent the risk of fire or electric shock, do not expose any part of the unit to rain or moisture.

If liquids are spilled on the surface, stop using immediately, allow unit to dry out and have checked by qualified personnel before further use.

Avoid impact, extreme pressure or heavy vibration to the unit.

There are no user serviceable parts inside the Z5M – refer all servicing to qualified service personnel.

Safety

  • Check that the supplied mains lead is in good condition and the supply voltage is correct.

  • Ensure signal leads are of good condition and connected to appropriate inputs/outputs

  • Do not allow any foreign particles to enter the unit through control or connector apertures

Placement

  • Keep out of direct sunlight and away from heat sources.

  • Keep away from damp or dusty environments.

  • When rack-mounting, avoid placing heavy units above the unit and ensure all connectors and controls are accessible

Cleaning

  • Use a soft cloth with a neutral detergent to clean the casing as required

  • Use a soft brush to clear debris from the control surface

  • Do not use strong solvents for cleaning the unit.

Front Panel

Rear Panel

Applications

The Z5M can be used for any multi-output setup and is ideally suited to controlling a multi-room zoning sound system with up to 5 stereo or mono zones. Individual zones can be selected as mono if speaker placement is not conducive to stereo imaging. 2 separate stereo inputs can be selected or blended at will for each zone, opening up the possibility of separate program material for specific zones.

Connection

All connections are via balanced XLR and operate at line level. Use good quality XLR signal leads to connect the source signals to LINE 1 and LINE 2 inputs. Each output should be connected to the respective amplifier or active speakers for the particular zone, again using good quality XLR signal leads. Connect mains using the supplied IEC lead.

Operation

Set amplifier and active speaker volume levels fully down

Turn levels for each zone fully down to “MIN” (for both LINE 1 and LINE 2 sources)

Select MONO for any zones that are better suited to mono output.

Press the POWER switch on and play the signals connected to LINE 1 and LINE 2 inputs.

The LINE SIGNAL LEDs should indicate the presence of each input signal.

Gradually increase and then decrease the volume for LINE1 and LINE 2 to each zone in turn to check the output. Set the volumes and adjust for each source to each zone as required.

Before powering the Z5M down, turn down amplifier and active speaker volumes to avoid loud noises through the speakers.

Troubleshooting

Issue Solution
No function and Power switch LED is not lit Ensure mains voltage is correct (check selector) and connected properly
Ensure front panel power switch and mains outlet switch are on
Power is on but no audio output Check all XLR leads are OK and connected properly
Check that LINE 1 and LINE 2 controls are not all turned fully down
Check that inputs and outputs are connected the correct way around
Distorted output Reduce LINE 1 and LINE 2 level controls, increasing amp level to compensate
Reduce level of source signal(s) connected to LINE 1 and LINE 2 inputs
Ensure correct line level is selected on amplifier/active speaker inputs
Output is very low level Ensure input source is line level (0.775Vrms)
Increase LINE 1 and/or LINE 2 level controls,
Increase signal source level

Specification

Specification Value
Power supply 115/230Vac 50/60Hz (IEC)
Inputs Line 1 L+R, Line 2 L+R, balanced XLRF
Outputs Zone 1 to 5 L+R, balanced XLRM
Input impedance 40k Ohms
Output impedance 220 Ohms
Frequency response 20Hz - 25kHz, +0/-1dB
Signal to noise ratio >100dB
THD <0.005%
Dimensions 483 x 175 x 44mm
Weight 2.2kg

Precautions

CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit

Safety Notice

  1. Prior to use, read through this safety guide.
  2. Pay attention to safety warnings.
  3. Observe all operating requirements.
  4. For any items designed for indoor use only, do not operate near water or in humid environments.
  5. For cleaning, only use a lint-free, dry cloth.
  6. Install according to the specifications.
  7. Place away from heat sources or heating appliances.
  8. During placement, ensure adequate support for the product and access to controls and connectors.
  9. Do not obstruct any cooling vents or openings and allow adequate space for air flow.
  10. Use only power connections supplied with the product or suitable equivalents.
  11. Do not modify the equipment in any way.
  12. For any mains powered appliances, ensure that the mains voltage is as described in the specifications.
  13. Keep powered products and batteries away from the reach of children.
  14. In case of malfunction, water ingress or other damage, consult qualified service personnel.
  15. Avoid pressure or impact to the housing that may result in damage when transporting or installing this product.
  16. For any Earthed mains product, ensure that the power supply has a protective Earth connection.
  17. Keep all packaging materials out of reach of children.

Disposal : The "Crossed Wheelie Bin" symbol on the product means that the product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines.

AVSL Group Ltd, Unit 2 Bridgewater Park, Taylor Road, Manchester, M41 7JQ, Unitied Kingdom

AVSL (EUROPE) Ltd, Unit 3D North Point House, North Point Business Park, New Mallow Road, Cork, Ireland

Errors and omissions excepted. Last updated -